PR Electronics 2-wire transmitter with HART protocol
PR-5337D
RTD, TC, Ohm, and bipolar mV input
2 analog inputs and 5 device variables with status available
HART protocol revision selectable from HART 5 or HART 7
Hardware assessed for use in SIL applications
Mounting in hazardous gas and dust area
Product Enquiry
Product Enquiry
"*" indicates required fields
Application
- Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
- HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
- Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
- Amplification of bipolar mV signals to standard 4...20 mA current signals.
- Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
Technical characteristics
- HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
- The HART 7 protocol offers:
∙ Long Tag numbers of up to 32 characters.
∙ Enhanced Burst Mode and Event notification with time stamping.
∙ Device variable and status mapping to any dynamic variable PV, SV, TV or QV.
∙ Process signal trend measurement with logs and summary data.
∙ Automatic event notification with time stamps.
∙ Command aggregation for higher communication efficiency. - 5337D is designed according to strict safety requirements and is therefore suitable for applications in SIL installations.
- Continuous check of vital stored data.
- Meeting the NAMUR NE 21 recommendations, the 5337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 5337D meets NAMUR NE43 and NE89 recommendations.
Mounting / installation
- For DIN form B sensor head mounting.
- Configuration via standard HART communication interfaces or by PR 5909 Loop Link.
Further Information: https://www.prelectronics.com/products/temperature-transmitters/5300/2-wire-transmitter-with-hart-protocol-5337d/
CS Series
CSmicro Series
CTi Series
CT Laser Series
CS Laser Series
CT Ratio Series
CS Vision Series
Accessories for Pyrometers
IR Thermometer Configurator
Compact Line
Precision Line
Accessories for IR Cameras
Condition Monitoring Systems
IR Microscopes
Glass Inspection Systems
Industrial Packages
Furnace Package