IECEx Single or true dual inputs 2-wire HART 7 temperature transmitter

PR-6437D

IECEx 2-wire HART 7 temperature transmitter
RTD, TC, potentiometer, linear resistance and bipolar mV input
Single or true dual inputs with sensor redundancy and drift detection
Wide ambient operating temperature of -50 to +85°C
Total accuracy from 0.014%
2.5 kVAC galvanic isolation
Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications

Application

  • Temperature measurement of a wide range of TC and RTD types.
  • Conversion of wide span linear resistance and potentiometer inputs to 4...20 mA.
  • Conversion of bipolar mV signals to 4...20 mA.
  • Integration into asset management schemes.
  • Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.

Technical characteristics

  • True dual input transmitter, accepts the widest range of dual input combinations.
  • Sensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime.
  • Sensor drift detection - alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
  • Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and min./max. tracking.
  • Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
  • Extensive sensor matching including Callendar Van Dusen and custom linearizations.
  • Programmable input limits with runtime metering ensure maximum process traceability and sensor out of range protection.
  • IEC 61508 : 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
  • 6437xxSx is suitable for the use in systems up to Performance Level “d” according to ISO-13849
  • Meets NAMUR NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information.

Mounting / installation / programming

  • DIN rail mounting with up to 84 inputs per meter.
  • Configuration via PReset using PR5909 Loop Link / HART modem, or by Asset Management tool (e.g. Pactware, AMS, HART communicator).
  • The 6437D can be mounted in zone 0, 1, 2 and zone 21, 22 including M1 / Class I, Division 1, Groups A, B, C, D.

Further information
Supplier Product Page link: https://www.prelectronics.com/products/temperature-transmitters/6400/2-wire-hart-7-temperature-transmitter-6437d/

Data Sheets

Data_Sheet_PR-6437D
 