Thermocouples are used to measure temperature in a wide range of industries. Due to their simplistic design and vast measuring range, they have become one of the most commonly used methods of getting temperature readings that are essential to maintaining safety and quality in industrial processes such as power generation, mining, oil and gas, pharmaceutical, biotech, cement, paper and glass production.
There are a number of different types of thermocouples, with each one being used for a different temperature range, and therefore different industrial applications. Whatever the thermocouple type, one thing they have in common is that in an industrial setting, they typically pass the temperature reading to another system in the process.
Which systems receive data from a thermocouple?
The key systems that take data from a thermocouple include:
- Programmable Logic Controllers: (PLC) – a process control computer or industrial control system that manages and automates a specific process, machine, or whole production line.
- Data Capture Systems: In some applications, regular temperature readings need to be captured, stored and analysed.
- Temperature Display Units: if the temperature needs to be displayed in human readable format, it needs to be shown on a screen or an indicator.
- Remote Monitoring: applications where the monitoring site and the data capture and analysis location are separate, and the temperature data has to be transmitted over long distances and needs to be converted to a robust form, such as a current loop, to maintain signal integrity.
The need for signal conversion
However, the information that is produced by the thermocouple may not be compatible with the receiving systems.
It may be a question of format, where the receiving systems cannot use the ‘raw’ data from the thermocouple. It may also be an issue of the robustness of the signal – for example, if the signal needs to be sent across the plant room, or across the site or factory. The original signal may be in a format which is compromised over distance, or which is susceptible to corruption by Electro-Magnetic Frequency (EMF).
In these cases, a signal converter is used.
A signal converter converts one type of electrical or mechanical signal – the ‘input signal’ into another format – the ‘output signal’. It takes the output from the thermocouple and converts it into a higher level of electrical signal. This converted signal is in a format that the receiving system can read and use.
What signal conversion do you need?
Voltage or current conversion
Different devices require signals in different electrical forms, with some needing current as the input and others wanting voltage. For example, many industrial systems use 4-20mA current loops for long-distance signal transmission. In order for the thermocouple and the receiving system to communicate effectively, conversion from voltage to current, or vice versa, may be needed.
The 4-20 Milliamp signal
The most common conversion is to 4-20mA. The 4-20mA signal convention was first used in the 1950s. From its inception it was a game-changer, so much so that it has never been superseded. When it was developed, it was well received from an engineering point of view and has been well-accepted in the industry.
Since then, the 4-20mA convention has evolved to be part of the digital world. It has been enhanced and innovated, and digital implementation has been laid over it, with the digital signal travelling via the 4-20mA loop.
The 4-20mA convention is a simple, yet intelligent, signal, and one of the very few which is not influenced by the resistance of the cable (even digital information needs a boost to the signal). Neither is it compromised by Electro-Magnetic Frequency (EMF). A 4-20mA signal can be transmitted across 2.4 kilometres until intervention is needed, after which it can travel even further.
The 4-20mA signal is extensively used by the industries that use thermocouples for temperature sensing, and it is signal of choice for multiple applications. It is therefore the most common form of output signal in signal conversion.
2. Analog to digital conversion (ADC)
In some applications, you may need to convert from an analog to a digital signal. Many thermocouples produce an analog signal. If the receiving system can only read digital data, then analog to digital conversion is needed. For example, when it is sent to a PLC to control production equipment, it must be converted to digital format – in either an industry standard or a proprietary format.
Digital signals are less susceptible to noise than an analog signal, so ADC is also used in situations with a high level of electrical interference.
In summary, signal conversion plays a vital role in temperature monitoring – ensuring that devices can operate accurately, reliably and safely, especially in environments with electrical noise, high voltages, or complex system integrations. It ensures that temperature data is in a usable format, so your key industrial processes are managed safely and to the highest quality.
ECEFast offers expert solutions for thermocouples and signal conversion. Contact us today on 1800 818 811 for tailored assistance.
CS Series
CSmicro Series
CTi Series
CT Laser Series
CS Laser Series
CT Ratio Series
CS Vision Series
Accessories for Pyrometers
IR Thermometer Configurator
Compact Line
Precision Line
Accessories for IR Cameras
Condition Monitoring Systems
IR Microscopes
Glass Inspection Systems
Industrial Packages
Furnace Package