Designing smarter data centres: Why temperature monitoring should be built in from day one.

Technical | Data Centres
29/10/2026

Key Takeaways

  • Plan monitoring early: Incorporating temperature and environmental sensors into the initial design reduces installation costs, avoids retrofitting and ensures accurate sensor placement.

  • Accurate measurements improve efficiency: Monitoring temperature, humidity, airflow and pressure helps identify hotspots, optimise cooling and reduce unnecessary energy consumption.

  • Monitor critical cooling infrastructure: Environmental conditions, liquid cooling temperatures and supporting cooling plant all play an important role in maintaining data centre reliability.

  • Integrate with existing systems: Sensors provide accurate measurement data to a facility’s BMS or PLC, supporting real-time alarms, performance analysis and preventative maintenance.

  • Choose the right sensors: ECEFast helps designers and contractors select suitable sensing technologies to support reliable, efficient data centre operations.

Why accurate monitoring matters

Modern data centres are operating at higher power densities than ever before, particularly those supporting AI workloads. As heat loads increase, so too does the importance of understanding exactly what is happening within the cooling system.

Without accurate, real-time measurement, operators risk:

  • Localised hotspots that reduce equipment reliability.
  • Server throttling or unexpected shutdowns.
  • Higher energy costs caused by overcooling the facility “just in case”.
  • Cooling faults remaining undetected until equipment is affected.
  • Limited visibility of long-term cooling performance and trends.

Accurate measurement provides the data operators need to optimise cooling performance, improve energy efficiency and support preventative maintenance.

 

Three areas every modern data centre should monitor

1. Environmental conditions

The first layer of monitoring focuses on the data hall itself.

Typical measurements include:

  • Air temperature
  • Relative humidity
  • Dew point
  • Differential pressure
  • Air velocity

Together, these measurements help operators:

  • Detect hotspots before they become critical.
  • Verify that conditioned air is reaching the right locations.
  • Improve HVAC efficiency.
  • Reduce unnecessary energy consumption.
  • Minimise the risk of condensation and electrostatic discharge.

2. Liquid cooling performance

As AI drives higher rack densities, liquid cooling is becoming increasingly common in both new data centres and major upgrades.

Monitoring typically includes:

  • Supply water temperature
  • Return water temperature

These measurements help operators:

  • Verify that the cooling system is removing heat efficiently.
  • Detect developing issues such as blocked filters, pump faults or reduced flow.
  • Optimise cooling performance.
  • Reduce the risk of condensation around cooling infrastructure.

3. Cooling infrastructure

Depending on the design of the cooling system, additional monitoring may also be appropriate for supporting infrastructure such as:

  • Buffer tanks
  • Expansion vessels
  • Other critical cooling plant

Level sensors can provide measurement data to the facility’s control system, helping operators identify abnormal operating conditions and maintain system availability.

Data is where the real value lies

Collecting measurements is only part of the story. The real value comes from turning those measurements into actionable information.

Individual sensors provide accurate measurement data that can be integrated into the customer’s PLC, Building Management System (BMS) or other compatible monitoring and control platform. The customer’s system can then use this data to:

  • Receive real-time alarms when conditions move outside predefined limits.
  • View live dashboards showing environmental performance.
  • Analyse historical trends.
  • Optimise cooling strategies over time.
  • Support predictive maintenance.
  • Maintain comprehensive operational records.

The sensors provide the measurement data, while the customer’s connected control or monitoring system manages how that data is displayed, recorded, alarmed and analysed.

This enables a more proactive approach to managing cooling infrastructure while reducing operational risk.

E+E sensors for data centres

E+E offers a range of sensors for measuring critical conditions in and around the server rack, including temperature, humidity, differential pressure, airflow and condensation.

Individual sensors can be selected for each measurement point and integrated into the facility’s BMS, PLC or existing control system.

Why involve ECEFast early?

Considering environmental measurement early ensures the right sensors are positioned in the right locations, capturing the right data for the facility’s control system to measure, monitor and record.

ECEFast works with consultants, design engineers, contractors and facility operators to select the appropriate sensing technologies for each project’s cooling and environmental measurement requirements.

Rather than simply supplying sensors, ECEFast can provide:

  • Selection of the most appropriate sensing technologies.
  • Individual E+E Elektronik sensors and transmitters for temperature, humidity, pressure and airflow measurement.
  • Custom-designed water temperature probes for liquid cooling applications.
  • Level sensing where required.
  • Sensors suitable for integration with PLCs, Building Management Systems and other compatible customer control systems.
  • Installation, commissioning and calibration.
  • Ongoing technical support.

These individual sensors provide accurate, reliable measurement data that can be incorporated into the customer’s existing or specified control and monitoring system.

 

A smarter approach to data centre cooling

As Australia’s data centre sector continues to grow, designers face increasing pressure to deliver facilities that are resilient, energy-efficient and ready for future demands.

Temperature monitoring should no longer be viewed as an operational afterthought. By designing the right sensing and measurement points into the project from the beginning, operators gain the accurate data their control systems need to optimise cooling performance, reduce risk and protect critical infrastructure throughout the life of the facility.

In modern data centres, cooling keeps the servers running. Accurate measurement provides the data needed to prove that the cooling is doing its job.

 

Planning a data centre project?

Talk to ECEFast about selecting the right E+E sensors for accurate temperature, humidity, pressure and airflow measurement across your facility.

 

Frequently Asked Questions

K
L
Why should temperature monitoring be included in data centre design?

Planning temperature monitoring from the beginning ensures sensors are correctly positioned and integrated into the facility's control system. This improves measurement accuracy, reduces retrofitting costs and supports efficient cooling throughout the facility's life.

K
L
What environmental conditions should be monitored in a data centre?

Key measurements include air temperature, relative humidity, dew point, differential pressure and air velocity. These help operators detect hotspots, manage airflow, minimise condensation risks and maintain reliable operating conditions.

K
L
How can accurate temperature monitoring improve energy efficiency?

Accurate temperature measurements help operators understand cooling performance and identify areas of overcooling or insufficient airflow. This allows cooling systems to be adjusted based on actual conditions, potentially reducing energy consumption and operating costs.

K
L
What should be monitored in liquid cooling systems?

Supply and return water temperatures are important measurements for evaluating liquid cooling performance. They help operators assess heat removal, identify developing cooling issues and reduce the risk of condensation around critical infrastructure.

K
L
Can ECEFast sensors integrate with existing Building Management Systems?

Yes. ECEFast supplies sensors and transmitters suitable for integration with compatible Building Management Systems (BMS), PLCs and other control systems. These sensors provide measurement data, while the customer's connected system manages alarms, dashboards, reporting and analysis.

Brendan Dineen

Justin Marven

Managing director - ECEFast

Justin Marven is the Managing Director of ECEFast and has been helping Australian industry solve measurement and monitoring challenges for more than 30 years. Since joining ECEFast in 1997, Justin has progressed from Sales Manager to General Manager and now Managing Director, giving him a unique perspective on the technologies, industries and customers the business supports. His extensive experience in industrial instrumentation and process measurement enables him to share practical insights that help organisations improve safety, efficiency and operational performance.